CRC INDUSTRIES INC -- CONTACT CLEANER 2000, 02140 -- 7930-00N047770
=====================  Product Identification  =====================

Product ID:CONTACT CLEANER 2000, 02140
MSDS Date:06/15/1994
FSC:7930
NIIN:00N047770
=== Responsible Party ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINISTER
State:PA
ZIP:18974
Country:US
Info Phone Num:215-674-4300
Emergency Phone Num:215-674-4300
Preparer's Name:ADAM SELISKER
CAGE:CRCIN
=== Contractor Identification ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Phone:215-674-4300
CAGE:CRCIN
Company Name:CRC INDUSTRIES, INC.
Address:885 LOUIS DRIVE
Box:City:WARMINSTER
State:PA
ZIP:18974-2820
Country:US
Phone:215-674-4300/800-424-9300
CAGE:10136

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHANE, 1,1-DICHLORO-1-FLUORO-;
    (1,1-DICHLORO-1-FLUOROETHANE) (SARA 313)
CAS:1717-00-6
RTECS #:KI0997000
Fraction by Wt: 95-98%
Other REC Limits:500 PPM (MFR)
OSHA PEL:N/K 
ACGIH TLV:N/K 
Ozone Depleting Chemical:2

Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 3-6%
OSHA PEL:5000 PPM
ACGIH TLV:5000 PPM/30000 STEL

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATERIALS
    HAVE PRODUCED SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN
    LABORATORY ANIMALS AND COULD HAVE A SIMILAR EFFECT IN HUMANS.
    ADRENOMIMETICS (I.E., EPINEPHRINE) MAY BE C ONTRA-INDICATED EXCEPT
    FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY/CHRONICALLY EXPOSED TO
    CFCS . (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:ACUTE:INHALATION:DIZZINESS,
    LIGHTHEADEDNESS. HIGH LEVELS MAY CAUSE ASPHYXIATION OR CARDIAC
    ARRHYTHMIAS. SKIN:MAY CAUSE DEFATTING, IRRITATION. EYES:MAY CAUSE
    IRRITATION. CHRONIC:SKIN IRRITATIO N ON REPEATED CONTACT.
Medical Cond Aggravated by Exposure:IMPAIRED CARDIOVASCULAR FUNCTION
    SUCH AS CARDIAC ARRHYTHMIAS MAY BE SENSITIZED BY INHALATION.

=======================  First Aid Measures  =======================

First Aid:(IF SYMPTOMS PERSIST, CALL A PHYSICIAN). INHAL:REMOVE TO
    FRESH AIR. APPLY ARTIFICIAL RESPIRATION IF NECESSARY. EYES:FLUSH
    WITH LARGE AMOUNTS OF WATER FOR @ LEAST 15 MINUTES. SKIN:WASH AREA
    THOROUGHLY	WITH SOAP AND WATER. INGEST:DO NOT INDUCE VOMITING.
    GIVE WATER TO DRINK. GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:NONE
Lower Limits:7.6%
Upper Limits:17.7%
Extinguishing Media:WATER FOG, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
    & FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
    INCLUDE FLUORIDES, CHLORIDES, AND PHOSGENE . AEROSOLS MAY EXPLODE
    WHEN HEATED ABOVE 120F.

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE PERSONNEL. VENTILATE AREA. ABSORB
    SPILL WITH AN ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AEROSOL CAN MAY EXPLODE IF HEATED
    ABOVE 120F. VAPS ARE VERY HEAVY & WILL COLLECT IN LOW AREAS. OXYG
    WOULD BE DISPLACED & ASPHY COULD RESULT. (SUPDAT)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
    VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
    UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR
    PHOSGENE .

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:ABOVE TLV USE NIOSH/MSHA APPROVED SELF-CONTAINED
    BREATHING APPARATUS.
Ventilation:USE MECHANICAL MEANS IF NECESSARY TO MAINTAIN VAPOR CONC
    BELOW THE TLV.
Protective Gloves:SOLVENT RESISTANT.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGLES
Other Protective Equipment:ANSI APPRVD EMERGENCY EYE WASH & DELUGE
    SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HNDLG/STOR:GOOD VENT IS A MUST FOR LOW/CONFINED AREAS.
    1,1-DICHLORO-1-FLUOROETHANE IS SUBJECT TO SNUR RULES OUTLINED IN 40
    CFR 721.1007. TSCA EXPORT NOTIFICATION REQD.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:89.6F,32.0C
Vapor Pres:10 @ 70F
Vapor Density:4.1
Spec Gravity:1.24 @ 70F
Evaporation Rate & Reference:FAST
Solubility in Water:SLIGHT IN WATER
Appearance and Odor:CLEAR COLORLESS LIQUID WITH A FAINT ETHEREAL ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
POWDERED METALS SUCH AS ALUMINUM, MAGNESIUM, CALCIUM, ZINC. DO NOT
    STORE IN ALUMINUM CONTAINERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CHLORIDES, FLUORIDES . HALOGENS,
    HALOGEN ACIDS, POSSIBLY PHOSGENE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED
    OF IN CONFORMANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.